Gas Igniter Control

Sidac for Gas Igniter Circuit



Design Notes:

Protection Application:
Sidac devices are used as switch on device for Igniter Circuits. Operation Note: The resistor is usually chosen to achieve a spark interval of 100 â€" 250 mili second.
Solution Description:
For a voltage exceeding the Sidac breakover voltage point, the Sidac swathes on through a negative resistance region to a low on-state voltage. Der leitende Zustand bleibt so lange bestehen, bis der Strom unterbrochen wird oder unter den minimalen Haltestrom der Komponente abfällt. K2400G is commonly used in this application.
Companion Solutions:
K277 is new Sidac for high energy ignition systems which could replaces many GDTs.
Regulatory Issues:
Does not apply.
Unique Features:
Does not apply.
Application Warnings:
Does not apply.

Lösungen

Lösungen

  • K2400G

    Bidirektionale Standard-SIDACs