MLV SERIES

17th Nov 1999

Reliability Data Summary

Test Name Conditions Sample
Size
Rejects

High Temperature Operating Life 125° C ,1000Hrs , Vrated  500 0
High Temperature Storage 150° , 1000Hrs  500 0
Temperature Cycling -55° C , 25° C , 125° C
15Min , 5Min ,15Min
500 0
Peak Pulse  (8x20uS) 400 0
Energy    (10x1000uS) 400 0


MTBF = Mean Time Between Failures in Hours
C&K = Empirically derived constants
T = Absolute temperature (k) = T( C)+273
Note : 1 Failure in time (FIT) = 10^9 Hours at 55 C
Klow =

6649.4

Khigh =

13129.7

No units tested =

750

No units failed =

1

K

13129.7

MTBF = (e^(K/328-K/398))*(No units tested*1000) =

8.56E+08

FIT = 1/(MTBF/(No units failed *10^9)) =

1.167728

Note :In the model one failure in time has to be estimated in order for the calculations to be completed.


 

 



 