CH SERIES

17th November 1999

Reliability Data Summary

Test Name Conditions Sample
Size
Rejects

High Temperature Operating Life 125° C ,1000Hrs , Vrated  492 0
High Temperature Storage 150° , 1000Hrs  537 0
Temperature Cycling -55° C , 25° C , 125° C
15Min , 5Min ,15Min
90 0
Peak Pulse  (8x20uS) 790 0
Energy    (10x1000uS) 396 0


C&K = Empirically derived constants
T = Absolute temperature (k) = T( C)+273
Note : 1 Failure in time (FIT) = 10^9 Hours at 55 C 
Klow = 

6649.4

Khigh = 

13129.7

No units tested =

492

No units failed =

1

K

13129.7

MTBF = (e^(K/328-K/398))*(No units tested*1000)    =

5.62E+08

FIT = 1/(MTBF/(No units failed *10^9))      =

1.780073

Note :In the model one failure in time has to be estimated in order for the calculations to be completed. 


 

 



 


Legal Disclaimer & Privacy Statement